Laboratory dryers with natural or forced circulation

Laboratory dryers in capacity from 33 to 115 liters

DESIGNATION OF EG AND ET MODELS

Designation EG 40, EG 53 and EG 115 – the symbol EG means natural air circulation inside the dryer space.

ET 40, ET 53 and ET 115 – the ET symbol means forced air circulation inside the dryer space.

Dryer capacity and loading:

  1. Models EG 40 and ET 40 – the interior capacity of the dryer is 33 liters and a maximum load of 30 kg.
  2. Models EG 53 and ET 53 – the dryer has a capacity of 53 liters and a maximum load of 35 kg.
  3. Models EG 115 and ET 115 – the dryer has a capacity of 115 liters and a maximum load of 45 kg.

Laboratory heating and dryer, offer details

Product features

SHORT TIME OF HEATING UP

The new designed heaters, proper insulation and steering algorithm of process allow to reach temperature 150O C in less than 24 minutes.

INTERIOR`S PURITY

The rounded corners were priority under designing of oven’s interior. Because of safety and easy handling of a device.

FOUR WORKING MODES

Depending on your needs we offer four available modes: hours, circadian, continuous and a function of delay-start

LAYOUT OF SHELVES

The walls of the oven provide ease in sharing of working space and optimise placing of the products even large-size.

STABLE TEMPERATURE

Algorithm ALPI-TEMP controlling work of the heaters prevent before uncontrolled fluctuation of temperature.

LOADING CAPACITY UP TO 45 KG

Maximum loading capacity of the oven is 45 kg. Stainless steel and proper profile of the shelves allow for loading every shelf even up to 15 kg.

SEE MORE AND DOWNLOAD FOLDER

PRODUCT DETAILS

  1. Due to proper thermal insulation the losses of the heat were reduced what gives a real savings in the cost of electricity.
  2. Double security system. The heating ovens are equipped in two separate systems protecting before exceeding maximum temperature: electrical and mechanical under the norm DIN 12880:2007.
  3. Specially designed and made rounded corners provide ease in maintain cleanliness of device.
  4. Separately from sample’s height is possible to adjust height of the oven’s interior.
  5. User friendly control panel with easy access to all functions and settings, one touch – one function.
  6. The measurement’s precision and stability of the temperature provides – PT100 platina sensor.
  7. The door opens maximum at an angle 105° what mark easy and better access to oven’s interior.
  8. Four operating modes:
    • hours : possible setting from 1 minutes to 99 hours and 59 minutes
    • circadian: setting from 1 to 99 days
    • continuous: process of heating is stop by user.
    • function of delayed-start: possible setting of delayed-start even to 99 hours
  9. The interior is made of hygienic stainless steel. It is allowed to use in pharmaceutical, food and similar industry.
  10. External housing is made of powder painted steel.
  11. The warranty is 24 months. A device is designed and made in Poland. We provide full warranty and after-guarantee service.
  12. For more than 11 years we produce the laboratory equipment providing our Clients tried & tested quality and trouble free design.
  • Capacity: 33 litres
  • Air convection: natural
  • Range of temperature: from 50° Celsius to 250° Celsius
  • Loading capacity: 30 kg
  • Numbers of racks  (standard/maximum): 2/4
  • Heating time to 150° Celsius: 36 minutes
  • Recovery time to 150° Celsius after opening a door by 30 seconds: 11 minutes
  • External dimensions ( width/length/height in mm): 565 x 524 x 594
  • Internal dimensions ( width/length/height in mm): 345 x 319 x 296
  • “Open door” sensor: protect before uncontrolled fluctuation of temperature.
  • Capacity: 33 litres
  • Air convection: forced
  • Range of temperature: from 50° Celsius to 250° Celsius
  • Loading capacity: 30 kg
  • Numbers of racks (standard/maximum): 2/4
  • Heating time to 150° Celsius: 36 minutes
  • Recovery time to 150° Celsius after opening a door by 30 seconds: 11 minutes
  • External dimensions (width/length/height in mm) : 565 x 524 x 594
  • Internal dimensions (width/length/height in mm): 345 x 319 x 296
  • “Open door” sensor: protect before uncontrolled fluctuation of temperature.
  • Capacity: 53 litres
  • Air convection: natural
  • Range of temperature: from 50° Celsius to 250° Celsius
  • Loading capacity: 35 kg
  • Numbers of racks (standard/maximum): 2/4
  • Heating time to 150° Celsius: 35 minutes
  • Recovery time to 150° Celsius after opening a door by 30 seconds: 12 minutes
  • External dimensions (width/length/height in mm): 625 x 614 x 632
  • Internal dimensions (width/length/height in mm): 345 x 319 x 293
  • “Open door” sensor: protect before uncontrolled fluctuation of temperature.
  • Capacity: 53 litres
  • Air convection: forced
  • Range of temperature: from 50° Celsius to 250° Celsius
  • Loading capacity : 35 kg
  • Numbers of racks (standard/maximum): 2/4
  • Heating time to 150° Celsius: 26 minutes
  • Recovery time to 150° Celsius after opening a door by 30 seconds: 7 minutes
  • External dimensions (width/length/height in mm): 625 x 614 x 632
  • Internal dimensions (width/length/height in mm): 405 x 409 x 335
  • “Open door” sensor: protect before uncontrolled fluctuation of temperature.
  • Capacity: 115 litres
  • Air convection: natural
  • Range of temperature: from 50° Celsius to 250° Celsius
  • Loading capacity : 45 kg
  • Numbers of racks (standard/maximum): 2/6
  • Heating time to 150° Celsius: 34 minutes
  • Recovery time to 150° Celsius after opening a door by 30 seconds: 12 minutes
  • External dimensions (width/length/height in mm): 685 x 750 x 750
  • Internal dimensions (width/length/height in mm): 463 x 544 x 456
  • “Open door” sensor: protect before uncontrolled fluctuation of temperature.
  • Capacity: 115 litres
  • Air convection: forced
  • Range of temperature: from 50° Celsius to 250° Celsius
  • Loading capacity: 45 kg
  • Numbers of racks (standard/maximum): 2/6
  • Heating time to 150° Celsius: 24 minutes
  • Recovery time to 150° Celsius after opening a door by 30 seconds: 6 minutes
  • External dimensions ( width/length/height in mm) : 565 x 524 x 594
  • Internal dimensions ( width/length/height in mm) : 463 x 544 x 456
  • “Open door” sensor: protect before uncontrolled fluctuation of temperature.

Warranty:

24 months – product fully designed and made in Poland, we provide full warranty and post-warranty service.

Transport:

Cardboard packaging with polystyrene protection.

A little bit of statistic

DRYERS OVENS IN NUMBERS
1
NUMBER OF EG AND ET dryer models
1
ACCEPTABLE LOAD CAPACITY PER SHELF
1
COUNTRIES USE ALPINA DRYERS